Cladding render brickwork

AAC/Hebel panel installation, alignment, and jointing defects

3 examples in 3 videos 3 major

What it is

Hebel aerated concrete blocks were laid without specified adhesive at butt joints, leaving gaps filled crudely with expanding foam. The base is missing a damp-proof course, resulting in block cracking and moisture vulnerability.

The contractor installed 50 mm thick aerated concrete wall panels instead of the 75 mm panels specified on the drawings. This non-conforming substitution affects structural and acoustic performance.

The wall was incorrectly stepped out by approximately 75 mm instead of finishing flush, using an extra panel. Additionally, required expansion joints and drainage falls were completely omitted.