Inspection Library

Cladding render brickwork

Blocked, covered, or obstructed weep holes

4 examples in 4 videos 2 major 2 minor

What it is

Weep holes in the brick veneer perimeter are completely obstructed by excess mortar droppings. Blocked openings prevent cavity ventilation and moisture drainage from exiting the wall assembly.

Weep holes in the perimeter brickwork are buried beneath garden level and soil rather than remaining clear above finished ground level. This prevents cavity ventilation, inhibits drainage, and creates a termite inspection breach.

Perimeter weep holes intended to drain cavity moisture are buried by landscape fill. Obstructing weep holes prevents cavity drainage and increases risk of damp ingress.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Drainage stormwaterSite works landscaping

Video examples