Cladding base moisture sealing and coating omissions
What it is
Contractors attempted to seal all external gaps on the timber cladding with silicone, trapping water inside the cavity. Sealing the corner trim prevents moisture from freely draining downwards and escaping to the exterior.
No damp-proofing seal was installed beneath the aerated concrete panels at the base of the wall. In addition, the applied coating fails to meet manufacturer specification for weatherproofing.
Standards
- AS 5146.1 Suggested reference, unverified
- NCC Suggested reference, unverified
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.