Cladding Batten Installation Defects
What it is
Cavity battens supporting timber cladding exceed the maximum 450 mm spacing requirement, terminating around 600 mm apart. Furthermore, drainage packers between battens and wall wrap are missing, preventing vital cavity airflow and moisture dissipation.
Battens supporting the James Hardie Axon cladding were fixed horizontally rather than vertically. This obstructs the vertical cavity airflow required to vent the wall system and breaches manufacturer specifications.
Standards
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to