Cladding Ground and Soil Clearance
What it is
Timber boards installed without adequate ground clearance were improperly coated with liquid waterproofing membrane instead of being given required physical clearance. This traps moisture behind the timber and leaves the exposed membrane vulnerable to UV damage and peeling.
The autoclaved aerated concrete wall panels are recessed below ground level, leaving them vulnerable to soil contact and moisture penetration. Additionally, the surface reinforcement mesh was simply nailed on rather than embedded within the base coat, voiding manufacturer compliance.
External cladding materials including polystyrene, brick, and Weathertex are embedded directly into the garden soil. The required clear separation between the bottom edge of the cladding and the finished ground level is absent.
Standards
- AS 3959 Suggested reference, unverified
- NCC Suggested reference, unverified
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Site works landscapingWaterproofing wet areas
Video examples
- Builder Fired! You Won’t Believe What Happened Next on This Site 34:20 majorInappropriate membrane application over ground-contact timber cladding
- $2.1 Million To Build & $250,000+ To Manage! 9:33 majorRecessed Hebel cladding retaining soil and unbonded reinforcing mesh
- $1M Home Disaster! This Builder’s Mistakes Will SHOCK You! 2:36 majorWall cladding embedded in soil without ground clearance
- This Is How Families Lose Everything When Building A Home 29:20 majorInadequate ground clearance below cladding causing rot