What it is

An approximate 60 mm gap is visible in the external wall assembly, demonstrating defective workmanship. The opening exposes the wall junction to the elements.

PermaTimber composite cladding boards were butt-jointed along a 6.5 metre span instead of using required expansion joints. This violates manufacturer instructions and voids warranty.