Cladding Installation Gaps and Expansion Joints
What it is
An approximate 60 mm gap is visible in the external wall assembly, demonstrating defective workmanship. The opening exposes the wall junction to the elements.
PermaTimber composite cladding boards were butt-jointed along a 6.5 metre span instead of using required expansion joints. This violates manufacturer instructions and voids warranty.
Standards
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Video examples
- Off The Plan Disaster Revealed! 1:41 minorExcessive gap in external cladding installation
- Off The Plan Disaster Revealed! 2:53 majorButt-jointed composite cladding without expansion trim