Cladding Not to Approved Plans / Specifications
What it is
None of the lightweight claddings installed across the two-storey house match the approved plans. The builder substituted approved materials with unauthorised alternatives across various elevations.
The builder installed 50 mm thick autoclaved aerated concrete panels rather than the 75 mm Hebel specified on the drawings. In addition, the panels lack back-blocking, allowing the wall lining to move freely in and out.
The exterior cladding was changed from vertical Stria to horizontal profile, corrugated cladding replaced specified Longline sheeting, and the angled spotted gum timber facade was built straight. These unapproved alterations breach requirements to construct in accordance with approved plans.
Standards
- Building Act 2004 (ACT) s 42 Suggested reference, unverifiedReference not matched
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.