Cladding Roof and Clearance to Cappings / Planters
What it is
The fibre cement wall cladding panels do not maintain the required 50 mm clearance above the lower metal roof line. This inadequate separation can trap moisture and cause premature panel deterioration.
External fibre cement wall sheets terminate hard against the roof and planter capping without providing the mandatory 50 mm clearance gap.
Fibre cement wall cladding is installed hard down against the roof capping rather than maintaining the required 50 mm clearance. Moisture is trapped behind the unsealed joint, causing water to bypass the Z-flashing and enter the structure.
Standards
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I Uncovered a $1.1M NSW Building Catastrophe 7:47 majorInadequate clearance between fibre cement cladding and roof
- I Uncovered a $1.1M NSW Building Catastrophe 16:39 majorNo vertical clearance at planter box wall cladding
- This Homeowner Thought He Found a $3m Dream Home … 27:26 majorWall cladding installed hard down onto metal capping without clearance