Inspection Library

Cladding render brickwork

Cladding Roof and Clearance to Cappings / Planters

3 examples in 2 videos 3 major

What it is

The fibre cement wall cladding panels do not maintain the required 50 mm clearance above the lower metal roof line. This inadequate separation can trap moisture and cause premature panel deterioration.

External fibre cement wall sheets terminate hard against the roof and planter capping without providing the mandatory 50 mm clearance gap.

Fibre cement wall cladding is installed hard down against the roof capping rather than maintaining the required 50 mm clearance. Moisture is trapped behind the unsealed joint, causing water to bypass the Z-flashing and enter the structure.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Roofing

Video examples