Cladding to roof clearance
What it is
The external timber cladding only maintains a 9 mm to 15 mm gap above the lower roof decking instead of the manufacturer-specified 70 mm clearance. This inadequate separation voids warranty and exposes the cladding edge to continuous water soaking.
The wall cladding and fire-rated plasterboard are installed hard against the roof cladding instead of maintaining a mandatory 50 mm clearance. This allows moisture to wick up into the cladding and fire-rated lining, leading to deterioration.
External cladding does not maintain the required 50 mm clearance above the metal roof profile, and multiple fixing nails protrude rather than sitting flush with the cladding surface.
Standards
- AS 1562.1 Suggested reference, unverified
- NCC Suggested reference, unverified
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Fire safety smoke alarmsRoofing
Video examples
- I Inspected A Bankrupted Builder’s Project… 18:16 majorInsufficient clearance between wall cladding and roof sheeting
- Post Inspection | Unbelievable $200,000 Rectification… 10:06 majorInadequate clearance between wall cladding and roof surface
- I Unraveled a $750K Construction Disaster: NSW Build Exposed! 27:50 minorInsufficient cladding clearance to roof and protruding fastener heads