Discontinuous, interrupted, or compromised expansion joints
What it is
Panels remain butted tightly together behind a shallow surface line that fails to provide a genuine gap. Because the cut does not isolate the panels, cracking propagates away from the joint line.
An expansion joint in the Hebel wall cladding stops prematurely instead of running the full height of the wall. Full-height expansion joints are required by the manufacturer to accommodate wall movement.
The exterior articulation expansion joint does not continue cleanly through the structure. Additionally, adjacent flashing tapers unevenly rather than maintaining true alignment.
Standards
- AS 3700 Suggested reference, unverified
- AS 5146.1 Suggested reference, unverified
- HB 39 Suggested reference, unverified
- NCC Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- The Ugly Truth of New Homes: Exposing Neglect and Deception 2:24 majorSuperficial cosmetic groove disguising missing full-depth joint
- I Inspected Her Brand New Home… It’s Worse Than It Looks 4:55 minorDiscontinuous Hebel wall vertical expansion joint
- I Uncovered a Nightmare: Inside the ~$2 Million Townhouses of West Melbourne 44:11 minorDiscontinuous expansion joint and tapering roof flashing