Inspection Library

Cladding render brickwork

Insufficient cladding ground and roof clearance

3 examples in 3 videos 2 major 1 minor

What it is

The suspended cladding edge terminates nearly flush with only around 5 mm of overhang instead of the specified 50 mm clearance. This inadequate drip clearance allows runoff to track back inside the assembly.

Cladding sheets were secured with overdriven brad nails rather than the fasteners specified by the manufacturer. Clearances from the bottom edges of boards to the roof flashings fail to meet the required 10 mm and 50 mm separations.

The Scyon Axon wall cladding panels are installed with only 10 mm clearance above the roof deck. The manufacturer installation manual specifies a minimum clearance of 50 mm to avoid moisture uptake and preserve warranty.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Roofing

Video examples