Masonry structural piers and height deficiencies
What it is
A single-skin brick subfloor infill wall was erected without engaged piers to provide lateral stability. Despite the lack of structural support, the engineer improperly approved the installation.
A subfloor masonry wall measuring 3.6 metres in height was constructed without engaged piers. For the designated wind rating, spacing rules require stabilizing piers, none of which were installed.
The brick boundary wall measures 230 mm in width rather than the 300 mm dimension specified on the structural drawings. The wall also lacks the mandatory 20 MPa grout core-filling and reinforcement steel detailed in the engineering plans.
Standards
- AS 4773.1 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Footings slabStructural framing
Video examples
- They Approved THIS?! Engineer Caught in Major Mistake! 11:09 majorSingle-skin masonry subfloor wall constructed without stabilizing piers
- They Approved THIS?! Engineer Caught in Major Mistake! 13:01 majorExcessive 3.6m masonry wall height lacking mandatory piers
- I inspected a $500K Dangerous Extension 2:48 majorBoundary wall width undersized and missing specified core-filling