Missing Corner Trims and Flashings
What it is
Required internal corner flashings were omitted in favor of makeshift timber strips that displaced under thermal movement. The sarking and timber framing behind the junction are exposed due to missing weatherproofing components.
The installation omits the manufacturer's specified external angle trims, utilizing ad-hoc timber pieces instead. The substitution fails to provide proper edge protection and weatherproofing for the cladding system.
The external corners of the fibre cement cladding lack proper corner profiles, weather seals, or corner flashings. The junctions were crudely wrapped, leaving open gaps vulnerable to moisture penetration.
Standards
- AS 4055 Suggested reference, unverified
- AS 4200.2 Suggested reference, unverified
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- Award-Winning Builder's $600K Flop? A Queensland Inspection Shocker! 9:46 majorMissing manufacturer internal corner flashings on cladding
- Award-Winning Builder's $600K Flop? A Queensland Inspection Shocker! 10:38 minorOmission of proprietary external corner trims on cladding
- Worst Builder 2024 End Game! 28:24 majorMissing external corner trims and flashings on fibre cement cladding
- Unveiling Worst Builder of 2024 52:06 majorMissing flashing and corner trims behind cladding boards