Inspection Library

Cladding render brickwork

Missing or omitted vertical expansion and movement control joints

4 examples in 4 videos 3 major 1 minor

What it is

Vertical movement control joints were completely omitted along internal and external junctions of the Hebel walls, causing extensive masonry cracking.

Autoclaved aerated concrete wall panels were erected with completely omitted vertical and horizontal movement control joints on internal and external corners and around wide openings. The unarticulated panels and underlying blueboard are fracturing under natural building movement.

Materials have been installed hard against the rendered exterior wall without an allowance for thermal expansion and contraction movement. Expanding materials filled improperly with expanding foam will crack and cause joint failure.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Finishes painting tiling

Video examples