Missing or omitted vertical expansion and movement control joints
What it is
Vertical movement control joints were completely omitted along internal and external junctions of the Hebel walls, causing extensive masonry cracking.
Autoclaved aerated concrete wall panels were erected with completely omitted vertical and horizontal movement control joints on internal and external corners and around wide openings. The unarticulated panels and underlying blueboard are fracturing under natural building movement.
Materials have been installed hard against the rendered exterior wall without an allowance for thermal expansion and contraction movement. Expanding materials filled improperly with expanding foam will crack and cause joint failure.
Standards
- AS 3700 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- This Is How Families Lose Everything When Building A Home 1:10:59 majorOmitted vertical expansion control joints in Hebel wall
- I Inspected A Bankrupted Builder’s Project… 23:37 majorMissing movement and control joints on external Nasahi panels
- Investor's Nightmare: What the Previous Inspector Missed?…. 7:17 minorNo expansion gap provided against rendered wall surface
- Buying a Home in Australia? Watch This First to Avoid Costly Mistakes! 22:41 majorExternal AAC corner wall lacks required vertical movement joint