Missing weep holes and flashing
What it is
Where the lower roof meets the upper masonry wall, there is no upturned apron flashing, damp-proof course, or weep holes. Any rainwater or internal condensation will drain directly into the ceiling void below.
Weep holes were completely omitted at the base of the brickwork along the slab rebate, preventing wall cavity drainage. Additionally, an existing weep hole above an opening is fully blocked with mortar.
Standards
- AS 4773.2 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Drainage stormwaterFootings slabRoofing