Inspection Library

Cladding render brickwork

Non-compliant Hebel Panel Installation

4 examples in 4 videos 4 major

What it is

Hebel panels were installed directly on top of temporary fencing concrete pads without protective coating or weather sealing. Furthermore, the installation lacks the required expansion and movement joints across the wall sections.

The external Hebel autoclaved aerated concrete wall panel is left unsealed and fully open. This leaves the internal structural framing vulnerable and exposed to external elements.

No continuous damp-proof course was installed between the bottom of the Hebel panels and the concrete slab perimeter, violating the Certificate of Conformity and permitting rising damp.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Footings slabStructural framingWaterproofing wet areas