Wall sarking installation defects
What it is
The pliable building membrane behind the wall does not have the mandatory 150 mm overlap or taped seams, compromising weather and fire barrier integrity.
Wall sarking was left unengaged and does not extend into the bottom starter strip as required by the manufacturer's manual, allowing water ingress behind the cladding system.
Non-breathable reflective foil was installed hard against framing without drainage cavity battens, trapping condensation and causing rot behind polystyrene cladding.
Standards
- AS 4200.2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- Unbelievable! Building Surveyor Approved This... 5:03 minorWall sarking joints lack required 150 mm overlap or tape
- This Is How Families Lose Everything When Building A Home 27:52 minorWall sarking not engaged into starter strip
- This Is How Families Lose Everything When Building A Home 1:16:27 majorNon-breathable foil sarking installed hard against timber