Cladding render brickwork

Weep holes missing, covered, or clearance defects

3 examples in 2 videos 3 major

What it is

Weep holes have been omitted along the base of the perimeter walling. Trapped cavity moisture cannot properly drain out.

Perimeter weep holes are completely buried or obstructed by the finished ground level. Additionally, the required ground fall away from the building in this high rainfall intensity area is not maintained.

The weep holes provide only around 12 mm of ground clearance instead of the mandatory 50 mm clearance. This inadequate height allows moisture ingress into the wall cavity.