What it is

Required 300 mm by 300 mm surface drainage pits were omitted from specified locations along the perimeter pathway and retaining areas. Retaining walls also lack core filling and proper agricultural subsoil drainage lines.

Perimeter drainage swales specified on the engineering plans were cut short, leading to extensive water pooling around the slab foundation. Roof downpipes remain disconnected from the stormwater system.

External paving lacks appropriate outward fall and slopes toward the structure. This causes surface water and silt to flow directly against the house.