Ceiling plasterboard back-blocking defects
What it is
Back-blocking strips installed behind plasterboard ceiling joints are undersized. They fail to extend the necessary 100 mm on either side of the recess line to prevent joint cracking.
Ceiling plasterboard sheets were installed without back-blocking along the recessed sheet joins. Omitting back-blocking increases the risk of joint cracking and ridging across ceiling spans.
Plasterboard ceiling lining sheet joints in the roof space lack back-blocking battens or strips. Omission of back-blocking leads to joint movement, cracking, and surface distortion in large ceiling spans.
Standards
- AS/NZS 2589 Suggested reference, unverified
- Australian Standards Reference not matched
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.