3 examples in 3 videos 1 major 2 minor

What it is

The open floor spans a length of 21 metres without any movement control joints, breaching manufacturer specifications that require an expansion joint every 15 metres. Island cabinetry was also installed tight against the boards without expansion gaps.

Engineered floating timber boards were installed continuously through doorways and hallways without intermediate expansion breaks. Each room section must be isolated by a movement joint so it can expand and contract as an independent raft.

A 5.9-metre span of external compressed sheet flooring lacks required movement control joints and does not provide adequate structural fall away from the dwelling. This breaches manufacturer specifications and voids warranty.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Cladding render brickworkDrainage stormwater