Deficient or missing reinforcement in edge and internal beams
What it is
The edge beam was constructed wider than the specified 300 mm dimension without adding the necessary supplementary reinforcement bars. Additional reinforcement is required for every 100 mm increase in width beyond the design specification.
The internal beam width measured 600 mm compared to the designed 300 mm width but only contained a single bar and trench mesh. The installation fails to provide an additional bar for each 100 mm of expanded beam width as specified.
Another section of the edge beam measured 532 mm in width instead of the standard 300 mm without installing supplementary steel. The extra rebars mandated for every 100 mm increase in width were completely omitted.
Standards
- AS 2870 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Video examples
- Pre-Pour Slab Alert: What the Surveyor Missed! 9:10 majorMissing extra reinforcement in widened edge beam
- Pre-Pour Slab Alert: What the Surveyor Missed! 11:07 majorInsufficient reinforcement in oversized internal beam
- Pre-Pour Slab Alert: What the Surveyor Missed! 12:18 majorMissing rebar in widened section of edge beam