Attic walkway and isolator switch defects
What it is
The attic access platform servicing the mechanical unit fails to meet the minimum width of 600 mm. In addition, no local lighting or control switch is installed adjacent to the roof cavity equipment.
No permanent maintenance walkway or platform is installed between the roof ceiling manhole and the ducted air handling unit, and the required local isolator switch is absent. Safe access and local electrical isolation are required for plant servicing.
Standards
- AS 4254.1 Suggested reference, unverified
- AS/NZS 3000 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.