Box gutter fall, slope, or reverse fall causing ponding
What it is
The box gutter falls backwards away from the sump with 27 mm of backfall, causing water and corrosive airborne salts to pond. Fasteners and rivets are already displaying premature rust.
The box gutter provides only 3 mm per metre fall against the mandatory minimum 5 mm per metre gradient, with zero fall in places. Additionally, its maximum depth reaches only 35 to 50 mm.
The box gutter was installed with fall in the wrong direction, leading to roughly 30 mm of standing water. Support brackets need re-adjustment to achieve correct fall towards the outlets.
Standards
- AS/NZS 3500.3 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- Builder LOSES IT During Inspection – Crazy Confrontation! 39:25 majorReverse fall and rusting fasteners in shallow box gutter
- Builder LOSES IT During Inspection – Crazy Confrontation! 43:49 majorInadequate slope and shallow depth along secondary box gutter
- I Reveal $900K Home Horror: NSW Building Inspection Gone Wrong! 12:46 majorBox gutter holding ponding water due to reverse fall