Gutter slope, valley gutter, and sarking overhang defects
What it is
The gutter slopes backwards with no outlet, while the valley gutter is narrower than 180 mm, lacks right-hand turn-ups, has unfolded edges, and sticks out over 50 mm into the gutter. These defects cause stormwater to flow into the home.
The roof sarking lacks the required 150 mm overlap at the ridge and the unsealed butt joint is non-compliant. Additionally, the sarking does not extend the minimum 25 mm into the eaves.
Standards
- AS 4200.2 Suggested reference, unverified
- HB 39 Said in video
- NCC Said in video
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I Inspected a Billionaire’s Mansion 1:07:28 majorIncorrect gutter slope and non-compliant valley gutter overhang