Parapet and roof capping joint and overlap defects
What it is
Cement sheet capping junctions lack proper anti-capillary breaks and have been poorly sealed with excessive silicone. Screws and nails are overdriven, leaving the assembly vulnerable to moisture penetration.
The parapet capping simply butts against the adjacent wall surface without a vertical upstand or protective counter-flashing. This junction creates an immediate pathway for moisture ingress behind the wall cladding.