Roof batten spacing and fixing defects
What it is
Roof tile battens are fastened directly to the steel roof frame using smooth nails rather than approved mechanical screw fixings. The connection relies merely on friction and fails to provide adequate uplift resistance.
The roof batten centres measure approximately 1.2 metres apart, exceeding the allowable 900 mm spacing limit.
Standards
- AS 1684.2 Suggested reference, unverified
- AS 2050 Suggested reference, unverified
- NASH Standard Residential and Low-Rise Steel Framing Part 1 / Part 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I Climbed Into the Roof Nobody Checked Before They Bought 9:00 majorRoof battens fixed to steel framing with nails instead of screws
- Unveiling WA’s Homes: Are These Australia’s Best Builds? 7:44 majorExcessive roof batten spacing