Inspection Library

Roofing

Roof sarking flashing and gutter discharge faults

3 examples in 3 videos 2 major 1 minor

What it is

Roof sarking extends past the edge of the flashing instead of terminating properly into it. Any condensation running down the membrane will bypass the flashing and penetrate interior wall cavities.

The pliable sarking membrane fails to extend into the box gutter by the required 25 mm minimum. This defect is allowing water to run back underneath the tiles and cause leaks downstairs.

The flexible roof underlay membrane terminates short and fails to turn down into the box gutter. Water tracking beneath the roof sheets will miss the drainage channel entirely.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Drainage stormwaterWaterproofing wet areas

Video examples