Roof sheet edge detailing and apron flashing fitment
What it is
Metal roof sheets lack turned-down ends at the gutter edge. In addition, apron flashings have not been notched to receive sheet ribs and are left loose and unsealed.
Adjacent roof sheets lack anti-capillary breaks at the side laps, and the box gutter upstand remains below minimum height. Capillary action will draw moisture past unsealed sheet edges.
Standards
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Video examples
- Rogue Builder Exposed: Illegal Construction Nightmare! 21:55 majorOmitted roof sheet downturns and poorly fitted apron flashings
- I Uncovered a Nightmare: Inside the ~$2 Million Townhouses of West Melbourne 17:05 majorRoof sheets missing anti-capillary breaks and low gutter upstand