Roof sheet fall, grading, and installation non-compliance
What it is
Portions of the metal roof exhibit insufficient fall to effectively drain water. Joints remain unsealed, flashings are bent or unsecured, and top capping is absent.
The roof sheeting is poorly cut, missing required screw fixings, and deflects excessively under foot traffic due to inadequate structural support. Furthermore, the guttering system slopes backwards, causing stormwater to pool rather than flow toward the downpipe.
The inspector notes in passing that the roof installation is non-compliant.
Standards
- AS 1562.1 Suggested reference, unverified
- AS/NZS 3500.3 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Drainage stormwaterStructural framing
Video examples
- Rogue Builder Exposed: Illegal Construction Nightmare! 26:52 majorInadequately graded roof sections, unsealed laps, and missing capping
- Less than 1 year old… 1:06 majorNon-compliant roof sheet installation, poor fall, and lack of support
- Watch a Builder Learn Her Project's Flaws! Body Cam 0:32 majorNon-compliant roof installation
- The Ghost Builder & the Haunted Home: Unmasking Construction Nightmares 0:48 majorRoof constructed straight across without planned cavity recess