Roof sheet overhang, gutter interface, and junction gaps
What it is
The eaves sheeting junction is completely open to the outside atmosphere without closure or sealing. This gap allows wind-driven rain direct access to structural timber inside the roof space.
Certain metal roof profile pans have not been turned down into the box gutter at the discharge edge. Failing to turn down the sheets increases the likelihood of water capillary action and wind-driven blowback.
On sawtooth roof profiles, the box gutter edge fails to meet the underside of the upper metal roof sheet, leaving open daylight directly into the roof space. This missing seal allows wind-driven rain to enter freely into the dwelling structure.
Standards
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Cladding render brickworkDrainage stormwaterStructural framing
Video examples
- Award-Winning Builder's $600K Flop? A Queensland Inspection Shocker! 4:52 majorOpen eaves lining allowing wind-driven rain penetration
- I Inspected A Bankrupted Builder’s Project… 19:19 minorUnturned roof sheet ends at gutter interface
- 2023's Most Costly Building Mistake… 32:47 majorGap between box gutter and roof sheeting exposing building interior
- I Unraveled a $750K Construction Disaster: NSW Build Exposed! 31:17 majorFascia lacks sufficient roof sheet overhang exposing timber frame
- Buying a Home in Australia? Watch This First to Avoid Costly Mistakes! 9:23 majorExposed building fabric and timber framing at roof junction