3 examples in 3 videos 2 major 1 minor

What it is

Roof sheeting is unsecured with several sections completely unsupported by battens. Flashings are unfastened, parapet capping is omitted, and sheet downturns are missing.

Pergola battens are left unfinished and incomplete, and the roof extension contains no flashings whatsoever at the junction with the existing house. This creates an immediate pathway for rainwater penetration and water damage.

The metal roof flashing is unsupported along its length, creating an unstable, flexible installation susceptible to water entry and wind detachment.