Inspection Library

Structural framing

Bolted timber connection and hardware defects

8 examples in 6 videos 8 major

What it is

Structural timber members are secured by bolts that engage only two threads without required washers, posing a severe structural safety risk. In addition, the floor joists bear onto an unlevel angle bracket leaning out of alignment.

Bolts are absent from structural steel connection plates in the subfloor framing. Where bolts were installed, they were not tightened properly and fail to exhibit the minimum required thread projection past the nut.

The connection between timber beams B6 and B2 was secured with only two screws and one internal joint. The required three M12 through-bolts on each side and specified bracing plates were completely omitted.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Video examples