Bolted timber connection and hardware defects
What it is
Structural timber members are secured by bolts that engage only two threads without required washers, posing a severe structural safety risk. In addition, the floor joists bear onto an unlevel angle bracket leaning out of alignment.
Bolts are absent from structural steel connection plates in the subfloor framing. Where bolts were installed, they were not tightened properly and fail to exhibit the minimum required thread projection past the nut.
The connection between timber beams B6 and B2 was secured with only two screws and one internal joint. The required three M12 through-bolts on each side and specified bracing plates were completely omitted.
Standards
- AS 1684 Said in videoSuggested reference, unverified
- AS 1684.2 Suggested reference, unverified
- AS 1720.1 Suggested reference, unverified
- AS 4100 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Video examples
- Are Homebuyers Getting Scammed…We Returned to the $2M Disaster 20:07 majorInsufficient bolt thread engagement and missing washers on timber connection
- Unveiling Worst Builder of 2023 28:06 majorMissing structural connection bolts and insufficient bolt thread engagement
- I Exposed Preston’s Worst Build: Police Called During Shocking Home Inspection! 1:16:50 majorMissing M12 bolts and bracing at beam B6 to B2 connection
- I Exposed Preston’s Worst Build: Police Called During Shocking Home Inspection! 1:26:29 majorMissing washers on truss bolts and separating brace straps
- I Hired Security to Do an Inspection: The Shocking Discovery the Builder Wanted Hidden! 25:31 majorOmitted internal connection brackets and improper bolt edge distance
- These Units That Shouldn’t Have Been Signed Off.. 21:09 majorUndersized M12 bolts installed at structural timber beam splice
- These Units That Shouldn’t Have Been Signed Off.. 24:18 majorTimber beam B14 skew-nailed instead of bolted via engineered steel cleat