Inspection Library

Structural framing

Defective and missing fixings in joist hangers

2 examples in 1 video 2 major

What it is

Several floor joist hanger brackets are missing the required number of Tek screws, with some flanges completely unfastened or substituted with inappropriate bugle screws and construction adhesive. Multiple structural load-bearing joists are held by as few as two or three fasteners.

A timber joist was secured using a mishmash of mismatched metal grips, a timber spacer, and a single bugle screw fitted with sheet flashing as an improvised washer into blockwork. The connection violates standard structural engineering details for joist supports.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Video examples