Defective bracing connections and panel hold-downs
What it is
Cable bracing runs directly through holes in the top and bottom chords without structural integrity or adequate tension. The connection lacks capacity and pulls away under slight movement, rendering the bracing ineffective.
Bracing panels lack engineered bolted hold-down fixings within 40 mm of the brace landing points, having only nail gun fixings installed far away from the connection. Nails lack the tensile uplift resistance required to hold down wall bracing systems.
Standards
- NASH Standard Part 2 Suggested reference, unverified
- NASH Standard Part 2 cl 3.2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to