Defective steel plates, welding, and fabrication
What it is
The steel post C4 connection to beams B14 and B9 lacks specified through-plates, bearing base plates, and structural welding shown on drawings. Three stacked washers were installed instead of the single washer permitted.
The structural steel portal frame lacks the 10 mm top cap plate, seat plate, and perimeter structural welds required by the engineering design.
Beams are supported on brackets connected by substandard welding to a reinforcement bar instead of approved structural connections. This improvised connection compromises the structural integrity of the frame.
Standards
- AS 4100 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Video examples
- I Exposed Preston’s Worst Build: Police Called During Shocking Home Inspection! 1:19:27 majorMissing structural plates, missing welds, and stacked washers at C4 post
- This Is How Families Lose Everything When Building A Home 1:20:56 majorOmitted top cap plate and seat plate welding on portal frame
- Post Inspection | Unbelievable $200,000 Rectification… 7:53 majorSubstandard bracket welding and reinforcement bar support