3 examples in 3 videos 3 major

What it is

The connection between the hip and truncated truss was omitted contrary to standard specifications. Additionally, the installed metal roof brace is undersized in cross-section dimensions and lacks the specified protective galvanised coating.

Toothed metal gang-nail connector plates are pulling away from the truss timbers and can be loosened by hand. Furthermore, triple grip connectors were installed without the requisite quantity and pattern of fasteners.

Creeper trusses exceeding 1.8 meters in span are fastened with only two nails per connection instead of three top and bottom nails. Furthermore, required chord tie plates are either absent or missing required fixing nails.