Girder truss improper lamination and fastening
What it is
A multi-ply girder truss was installed without being laminated together before being loaded with tiled roofing. The specified clamping bolts are missing or unthreaded with no nuts, causing the timber plies to separate under load.
Nail fixings connecting a double truss were spaced at 500 mm intervals rather than the maximum permitted spacing of 300 mm. The insufficient lamination has allowed the timber members to splay apart.
Standards
- AS 4440 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- $2.1 Million To Build & $250,000+ To Manage! 29:03 majorTriple girder truss unlaminated with missing bolts and nuts
- $2.1 Million To Build & $250,000+ To Manage! 32:15 minorExcessive nail spacing in double truss lamination