Inspection Library

Structural framing

Inappropriate or Defective Screws and Mechanical Fasteners

7 examples in 3 videos 7 major

What it is

A required strongback connection for the floor framing is defectively assembled, and screw fixings into the steel are installed too close to the member edges, compromising structural capacity.

Posi-strut floor joists are fastened into structural steelwork using brittle yellow zinc plasterboard screws rather than rated structural fixings.

Fasteners were driven directly along the extreme edge of the steel member rather than maintaining the required 1.5 screw diameters of edge distance. This defect risks edge blowout and structural connection failure.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Video examples