Inappropriate or Defective Screws and Mechanical Fasteners
What it is
A required strongback connection for the floor framing is defectively assembled, and screw fixings into the steel are installed too close to the member edges, compromising structural capacity.
Posi-strut floor joists are fastened into structural steelwork using brittle yellow zinc plasterboard screws rather than rated structural fixings.
Fasteners were driven directly along the extreme edge of the steel member rather than maintaining the required 1.5 screw diameters of edge distance. This defect risks edge blowout and structural connection failure.
Standards
- AS 1684 Suggested reference, unverified
- AS/NZS 4600 Suggested reference, unverified
- NASH Standard Part 1 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Video examples
- Are Homebuyers Getting Scammed…We Returned to the $2M Disaster 17:43 majorDefective strongback connection and screws positioned too close to edge
- Are Homebuyers Getting Scammed…We Returned to the $2M Disaster 19:18 majorPosi-struts secured to structural steel using plasterboard screws
- I Uncovered a Nightmare: Inside the ~$2 Million Townhouses of West Melbourne 34:17 majorStructural fixing screws installed too close to steel edge
- I Uncovered a Nightmare: Inside the ~$2 Million Townhouses of West Melbourne 37:29 majorFloor joist fixings driven on edge without double screwing
- Building Nightmares Unveiled: A Homeowner's Harrowing Journey Through Construction Chaos 10:10 majorInadequate screw fixings between wall frame and steel column
- Building Nightmares Unveiled: A Homeowner's Harrowing Journey Through Construction Chaos 43:52 majorPlywood bracing fixed with undersized screws lacking thread penetration
- Building Nightmares Unveiled: A Homeowner's Harrowing Journey Through Construction Chaos 59:04 majorNon-galvanized plasterboard screws used for structural ply bracing