Makeshift, defective, or loose packing and column support
What it is
The base of a structural column is packed up using plastic window packers and resting partially on turf without continuous solid support. This directly breaches standards requiring permanent, full continuous bearing.
Subfloor framing members have hollow gaps underneath with missing packing beneath load-bearing points. In other locations, unapproved and non-compliant materials were used to pack the bearers.
Load-bearing blocks and vertical studs have gaps measuring up to fourteen millimetres with loose, separating packers. The maximum allowable gap under specifications is ten millimetres.
Standards
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Cladding render brickworkFootings slab
Video examples
- I Inspected A Dangerous Build | Illegal Build Caught 10:08 majorSteel column supported on window packers and grass
- Unveiling Worst Builder of 2023 33:20 majorUnpacked bearer gaps and non-compliant packing materials
- I Exposed Preston’s Worst Build: Police Called During Shocking Home Inspection! 1:21:03 majorExcessive 14mm gaps under vertical members and loose packers
- I Uncovered a $1.1M NSW Building Catastrophe 28:06 majorSubfloor steel column supported on splitting makeshift blocks
- I Uncovered a $1.1M NSW Building Catastrophe 29:29 majorMakeshift loose stacked timber packing under structural framing