Inspection Library

Structural framing

Missing, compromised, or substandard wall frame bracing

9 examples in 6 videos 9 major

What it is

The approved engineering plans specify structural plywood wall bracing at this location, but none has been installed on the framing. Omission of designated wall bracing compromises the lateral stability and structural capacity of the frame.

Metal strap speed bracing is bent, sagging, and loose instead of being pulled straight and taut across the wall framework. The slack bracing fails to provide required racking resistance.

The approved structural drawings specify Type A structural plywood bracing, but metal strap Type B cross-bracing was substituted. Furthermore, the installation exceeds maximum height dimensions and flattens the bracing angle.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Cladding render brickwork

Video examples