Roof Truss Damage, Connections, and Support Defects
What it is
The bottom chord of a pre-engineered roof truss was cut through without engineering approval to make way for kitchen exhaust ducting. Cutting this member destroys structural tension load transfer and risks roof sag or localized collapse.
Toothed metal connector plates on the roof truss timber connections have pulled away from the timber chords. The detached nail plates compromise the joint's structural integrity and load capacity.
A hip truss is spanning across the roof space while resting on an intermediate jack truss, reversing the intended structural load paths. Unapproved framing arrangements require manufacturer verification and rectification.
Standards
- AS 4440 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- $2.1 Million To Build & $250,000+ To Manage! 21:52 majorSevered bottom chord of roof truss for rangehood duct installation
- $2.1 Million To Build & $250,000+ To Manage! 24:39 majorSeparating gang-nail connector plate on roof truss
- $2.1 Million To Build & $250,000+ To Manage! 25:17 majorImproper structural support arrangement between hip and jack truss
- $2.1 Million To Build & $250,000+ To Manage! 26:26 minorRoof bracing splice located too close to apex