Inspection Library

Structural framing

Roof Truss Damage, Connections, and Support Defects

4 examples in 1 video 3 major 1 minor

What it is

The bottom chord of a pre-engineered roof truss was cut through without engineering approval to make way for kitchen exhaust ducting. Cutting this member destroys structural tension load transfer and risks roof sag or localized collapse.

Toothed metal connector plates on the roof truss timber connections have pulled away from the timber chords. The detached nail plates compromise the joint's structural integrity and load capacity.

A hip truss is spanning across the roof space while resting on an intermediate jack truss, reversing the intended structural load paths. Unapproved framing arrangements require manufacturer verification and rectification.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Roofing

Video examples