Roof truss tie-down and bracing defects
What it is
Hip trusses are not tied down to the truncated girder truss using 84x1 mm Multigrip metal brackets as mandated by the approved truss layout and building standards. The required mechanical tie-downs are entirely missing.
The roof framing completely lacks required truss bracing and wall tie-down connections across the flat metal roof. Essential structural tie-downs were omitted entirely.
Trusses cut into half walls lack any physical tie-down connections to the supporting structure. Truss tie-downs are mandatory to resist uplift forces.
Standards
- AS 1684 Said in videoSuggested reference, unverified
- AS 1684.2 Suggested reference, unverified
- AS 4440 Said in videoSuggested reference, unverified
- NASH Standard Residential and Low-Rise Steel Framing Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I Hired Security to Do an Inspection: The Shocking Discovery the Builder Wanted Hidden! 51:07 majorOmitted Multigrip tie-downs between hip and girder trusses
- I Reveal $900K Home Horror: NSW Building Inspection Gone Wrong! 3:51 majorMissing roof truss bracing and wall tie-downs
- I Reveal $900K Home Horror: NSW Building Inspection Gone Wrong! 9:01 majorOmission of truss tie-downs
- I Climbed Into the Roof Nobody Checked Before They Bought 10:46 majorLoose top chord truss tie-down bracing strap