Inspection Library

Structural framing

Roof truss tie-down and bracing defects

4 examples in 3 videos 4 major

What it is

Hip trusses are not tied down to the truncated girder truss using 84x1 mm Multigrip metal brackets as mandated by the approved truss layout and building standards. The required mechanical tie-downs are entirely missing.

The roof framing completely lacks required truss bracing and wall tie-down connections across the flat metal roof. Essential structural tie-downs were omitted entirely.

Trusses cut into half walls lack any physical tie-down connections to the supporting structure. Truss tie-downs are mandatory to resist uplift forces.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Roofing

Video examples