Steel roof truss structural defects and alignment
What it is
Multiple steel roof trusses have suffered structural shearing and severe lateral twisting under roof loads. Makeshift steel patch plates were fixed without structural engineering details or manufacturer approval.
Multiple steel roof trusses deviate significantly out of plumb, measuring up to 42 mm per meter against the allowable limit of 20 mm or H/100. This out-of-plumb condition induces dangerous eccentric bending loads and potential instability.
Standards
- NASH Standard Part 2 Appendix A cl A2.3.3 Reference not matched
- NASH Standard Residential and Low-Rise Steel Framing Suggested reference, unverified
- NCC Vol 2 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I Climbed Into the Roof Nobody Checked Before They Bought 13:11 majorSheared and twisting steel roof trusses with uncertified patch repairs
- I Climbed Into the Roof Nobody Checked Before They Bought 18:32 majorSteel roof trusses out of plumb exceeding tolerances