Subfloor post head and bearer bracket deficiencies
What it is
Proprietary Spantec pier heads were mechanically forced apart and distorted to wrap onto non-matching subfloor posts. The brackets were secured with tek-screws contrary to manufacturer specifications, resulting in fractured connection points.
Newly erected steel subfloor columns are already developing surface corrosion due to missing concrete encasement and standing water. Supporting base bolts remain untightened without non-shrink grout, and bearer framing brackets were improperly welded.
Standards
No standards referenced.
Also relevant to
Video examples
- I inspected a $500K Dangerous Extension 19:50 majorModified and damaged proprietary pier head brackets on subfloor posts
- I inspected a $500K Dangerous Extension 28:49 majorCorroding new steel columns, unbolted bases, and substandard bearer brackets