Structural framing

Subfloor stump alignment and connection defects

4 examples in 2 videos 4 major

What it is

A subfloor stump is significantly tilted, deviating up to 73 mm out of plumb. The excessive inclination is exacerbated by soil saturation and standing water around its base.

Cross-bracing members on subfloor stumps exceeding 1500 mm in height were secured with only a single screw and nails instead of the required heavy-gauge screws or through-bolts. The undersized fixings are already distorting and failing.

Bearer connections at timber stumps lacked the mandatory galvanised iron tiedown straps and designated nail fixings. Where bearers join over support posts, one side was left completely unstrapped.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.