Inspection Library

Structural framing

Wall Frame Alignment, Plumbing, and Levelling

4 examples in 3 videos 4 major

What it is

A metal bracket with loose screws was substituted for the specified embedded timber base connection. Additionally, the surrounding framing is severely out of plumb by thirty-nine to forty-five millimetres.

Multiple wall frames across the units remain loose and insecurely fixed. Structural members lack traceability stamps or compliance certification, indicating the use of uncertified non-standard imported steel alongside branded framing.

Wall framing lacks continuous solid bearing, with bottom plates suspended above slab level or packed with non-durable particleboard scraps. Exposure to rain has caused the temporary shims to swell and decay, leaving wall studs ungrounded.

Standards

Explained in our own words. Check the current edition; which edition applies depends on the building permit date.

Also relevant to

Finishes painting tilingOther