Incomplete membrane coverage, pinholes, and general waterproofing defects
What it is
Waterproofing discontinues prematurely across multiple ensuites, leaving timber framing exposed. An unsealed floor penetration exposes downstairs plasterboard, and upper floor levels are uneven.
The applied waterproof membrane displays visible pinholes and poorly sealed junctions where moisture can penetrate. Exposed moisture-vulnerable timber framing materials risk swelling when water passes through the grout.
Standards
- AS 3740 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Finishes painting tilingStructural framing
Video examples
- Rogue Builder Exposed: Illegal Construction Nightmare! 7:56 majorIncomplete bathroom waterproofing, unsealed floor penetration, uneven floors
- Uncovering the Secrets: Confronting Supervisor over Leaks | BodyCam Footage 3:25 majorPinholes and unsealed membrane junctions over timber