Non-compliant shower hob construction and upstand height
What it is
The shower floor finishes flush with the raised hob instead of incorporating a compliant step-down threshold. Additionally, the bathroom doorway is located within 200 mm of the shower perimeter and lacks waterproofing membrane over the terminating angle, allowing water to escape behind wall linings.
The bathroom shower waterstop upstand measures approximately ten millimetres above the finished floor tiles instead of the mandatory minimum height. This deficiency allows water to escape over the containment boundary.
The bathroom shower hob lacks the mandatory 15 mm vertical waterstop separation above finished floor tiles, causing water to escape the enclosure. Active leaks were identified in multiple wet areas.
Standards
- AS 3740 Said in videoSuggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- I inspected a $500K Dangerous Extension 13:00 majorNon-compliant raised shower hob and unwaterproofed junction near doorway
- She Paid $20,000 For This Balcony. The Next Was $18,000 Cash 20:10 majorShower raised hob has inadequate upstand height above finished tiles
- This First-Time Homebuyer’s Nightmare Will Shock You! 21:14 majorNon-compliant shower hob height lacking 15 mm waterstop upstand
- Buying a Home in Australia? Watch This First to Avoid Costly Mistakes! 27:48 majorNo vertical membrane extension at hobbed shower doorway