Substrate preparation and priming defects
What it is
The waterproofing membrane appears to have been applied directly to the substrate without primer. Proper substrate priming is required to ensure adequate membrane adhesion.
Waterproofing liquid membrane was installed directly over contaminated, irregular concrete without mandatory surface smoothing or leveling. Failing to clean and prepare concrete substrates leads to tearing, pinholing, and debonding of the waterproofing film under service stress.
Membrane and primer coats were placed directly over heavy dust and debris without proper surface cleaning or compatible priming. The lack of substrate bond will prevent tile adhesive from adhering securely and cause system delamination.
Standards
- AS 3740 Suggested reference, unverified
- AS 3958 Said in video
- AS 3958.1 Suggested reference, unverified
Explained in our own words. Check the current edition; which edition applies depends on the building permit date.
Also relevant to
Video examples
- HOW NOT TO WATERPROOF! 0:00 majorSubstrate not primed prior to membrane application
- Balcony Leaks and Waterproofing Mistakes: Andrew Golle Reveals How to Avoid Them 53:45 majorInadequate substrate preparation and rough surface for membrane application
- I Caught This Waterproofing Contractor On Bodycam… 4:17 majorWaterproofing applied without priming on dusty, uncleaned substrate